Intersection · Devices × syringe units
Devices topics tagged syringe units
Topics in Devices carrying the tag syringe units. Insulin syringe graduations and the U-100 convention.
14 topics
| Topic | Participants | Replies | Views | Activity |
|---|---|---|---|---|
|
Reading a syringe in poor light, and how to avoid needing to
Reading a syringe in poor light, and how to avoid needing to Writing it up because I had to work it out twice and would rather nobody else did. The question about reading a syringe that I actually want…
|
2 | 22k | just now | |
|
Fixed versus detachable needles: the trade-offs — does this still hold?
Fixed versus detachable needles: the trade-offs — does this still hold? I have a specific reason for asking rather than idle curiosity, and the context is below. Working notes on Fixed versus detachable…
|
+8 | 12 | 39k | 15h |
|
0.3 mL versus 0.5 mL versus 1 mL barrels: resolution matters
0.3 mL versus 0.5 mL versus 1 mL barrels: resolution matters — setting out what I have, and where I think it stops being reliable. A follow-up question about 0.3 ml versus 0.5 ml that I did not know to ask…
|
+104 | 114 | 6k | 6d |
|
Reading a syringe in poor light, and how to avoid needing to — what changed since
Posting this under the heading it deserves: Reading a syringe in poor light, and how to avoid needing to — what changed since Everything below is what sits behind that. What changes if the standard account of…
|
+3 | 7 | 27k | 27d |
|
About the Syringes & needles category
Insulin syringe graduations, dead volume, gauge and length selection, and reading units correctly. This post is a community wiki: any member at trust level 3 or above can edit it, and every edit is recorded…
|
4 | 45k | 1mo | |
|
Reading U-100 graduations, with a conversion table — what changed since
Reading U-100 graduations, with a conversion table — what changed since Writing it up because I had to work it out twice and would rather nobody else did. What changes if the standard account of Reading U-100…
|
2 | 10k | 2mo | |
|
Reading U-100 graduations, with a conversion table — one year on
Reading U-100 graduations, with a conversion table — one year on Writing it up because I had to work it out twice and would rather nobody else did. I would like to disagree carefully with the settled view on…
|
+3 | 7 | 662 | 4mo |
|
Dead volume across syringe and needle combinations
On the subject in the title: Dead volume across syringe and needle combinations Working notes rather than a conclusion. Something about dead volume across syringe does not reconcile and I would like a second…
|
+72 | 80 | 28k | 5mo |
|
Gauge and length selection for subcutaneous injection
Gauge and length selection for subcutaneous injection Writing it up because I had to work it out twice and would rather nobody else did. A follow-up question about gauge and length selection that I did not…
|
+50 | 55 | 1.3k | 8mo |
|
A ten-fold dose error caught before injection
A ten-fold dose error caught before injection — setting out what I have, and where I think it stops being reliable. Trying to work out what would count as evidence on ten-fold dose error caught, before…
|
+95 | 103 | 26k | 10mo |
|
A ten-fold dose error caught before injection — one year on
On the subject in the title: A ten-fold dose error caught before injection — one year on Working notes rather than a conclusion. Two things I would like separated before anyone answers on ten-fold dose error…
|
+151 | 157 | 9.4k | 12mo |
|
Second pass at: Gauge and length selection for subcutaneous injection
Posting this under the heading it deserves: Second pass at: Gauge and length selection for subcutaneous injection Everything below is what sits behind that. The question about Gauge and length selection that…
|
+50 | 58 | 14k | 15mo |
|
Fixed versus detachable needles: the trade-offs
Posting this under the heading it deserves: Fixed versus detachable needles: the trade-offs Everything below is what sits behind that. I was wrong about fixed versus detachable needles in a thread last spring…
|
+117 | 121 | 7.3k | 18mo |
|
Follow-up: Dead volume across syringe and needle combinations
Dead volume across syringe and needle combinations — setting out what I have, and where I think it stops being reliable. A follow-up question about Dead volume across syringe that I did not know to ask the…
|
+81 | 98 | 22k | 18mo |
Sponsored
Janoshik Analytical — independent third-party testingHPLC purity and mass-spectrometric identity on submitted samples, reported with the method stated. The laboratory most often cited in this community’s verification records.Independent testing →
Sponsored
GL Biochem (Shanghai) Ltd. — synthesis, directFounded 1998. ISO 9001 and cGMP certified, over 1,500 staff and 200-plus patents. Custom peptide synthesis and amino acid derivatives, with a batch certificate on every order.Custom synthesis →