Devices topics tagged dead volume
Topics in Devices carrying the tag dead volume. Residual liquid in hub and needle, and the dose it silently removes.
33 topics
| Topic | Participants | Replies | Views | Activity |
|---|---|---|---|---|
|
Reading a syringe in poor light, and how to avoid needing to
Reading a syringe in poor light, and how to avoid needing to Writing it up because I had to work it out twice and would rather nobody else did. The question about reading a syringe that I actually want…
|
2 | 22k | just now | |
|
Revisiting: Drawing from a pen cartridge with a syringe: how the risk profile changes
Revisiting: Drawing from a pen cartridge with a syringe: how the risk profile changes Writing it up because I had to work it out twice and would rather nobody else did. Question about a metering device rather…
|
2 | 18k | 6h | |
|
Fixed versus detachable needles: the trade-offs — does this still hold?
Fixed versus detachable needles: the trade-offs — does this still hold? I have a specific reason for asking rather than idle curiosity, and the context is below. Working notes on Fixed versus detachable…
|
+8 | 12 | 39k | 15h |
|
Why a pen's dose steps are fixed and what that costs you
The question in the title: Why a pen's dose steps are fixed and what that costs you I will give what I have already checked below so nobody repeats it. A question about a device rather than about a compound,…
|
4 | 2.5k | 23h | |
|
Reading U-100 graduations, with a conversion table
Posting this under the heading it deserves: Reading U-100 graduations, with a conversion table Everything below is what sits behind that. A question about reading U-100 graduations that I think has a definite…
|
+35 | 41 | 2k | 1d |
|
Priming a pen and whether the primed volume is wasted
Priming a pen and whether the primed volume is wasted Writing it up because I had to work it out twice and would rather nobody else did. I have spent a fortnight trying to pin priming a pen down and I want to…
|
+19 | 23 | 1.3k | 2d |
|
0.3 mL versus 0.5 mL versus 1 mL barrels: resolution matters
0.3 mL versus 0.5 mL versus 1 mL barrels: resolution matters — setting out what I have, and where I think it stops being reliable. A follow-up question about 0.3 ml versus 0.5 ml that I did not know to ask…
|
+104 | 114 | 6k | 6d |
|
Reading a syringe in poor light, and how to avoid needing to — what changed since
Posting this under the heading it deserves: Reading a syringe in poor light, and how to avoid needing to — what changed since Everything below is what sits behind that. What changes if the standard account of…
|
+3 | 7 | 27k | 27d |
|
About the Syringes & needles category
Insulin syringe graduations, dead volume, gauge and length selection, and reading units correctly. This post is a community wiki: any member at trust level 3 or above can edit it, and every edit is recorded…
|
4 | 45k | 1mo | |
|
Reading U-100 graduations, with a conversion table — what changed since
Reading U-100 graduations, with a conversion table — what changed since Writing it up because I had to work it out twice and would rather nobody else did. What changes if the standard account of Reading U-100…
|
2 | 10k | 2mo | |
|
[2026 update] 0.3 mL versus 0.5 mL versus 1 mL barrels: resolution matters
On the subject in the title: 0.3 mL versus 0.5 mL versus 1 mL barrels: resolution matters Working notes rather than a conclusion. A follow-up question about 0.3 ml versus 0.5 ml that I did not know to ask the…
|
+108 | 124 | 27k | 2mo |
|
Reading U-100 graduations, with a conversion table — one year on
Reading U-100 graduations, with a conversion table — one year on Writing it up because I had to work it out twice and would rather nobody else did. I would like to disagree carefully with the settled view on…
|
+3 | 7 | 662 | 4mo |
|
About the Pens & autoinjectors category
Pen mechanics, dose counters, priming, and what happens when a pen is used off its label. This post is a community wiki: any member at trust level 3 or above can edit it, and every edit is recorded with its…
|
+1 | 5 | 92 | 5mo |
|
Dead volume across syringe and needle combinations
On the subject in the title: Dead volume across syringe and needle combinations Working notes rather than a conclusion. Something about dead volume across syringe does not reconcile and I would like a second…
|
+72 | 80 | 28k | 5mo |
|
Filter needles: when they help and what they cost you
On the subject in the title: Filter needles: when they help and what they cost you Working notes rather than a conclusion. Trying to work out what would count as evidence on filter needles, before collecting…
|
+45 | 50 | 19k | 5mo |
|
Coming back to: Pen dose counters: what a click does and does not guarantee
Pen dose counters: what a click does and does not guarantee — setting out what I have, and where I think it stops being reliable. Reading back through what has been written here about Pen dose counters, three…
|
4 | 105 | 5mo | |
|
A pen that felt like it delivered nothing: diagnosing it afterwards
On the subject in the title: A pen that felt like it delivered nothing: diagnosing it afterwards Working notes rather than a conclusion. Question about a metering device rather than about a syringe, because…
|
+35 | 39 | 584 | 6mo |
|
Pen mechanics when the cartridge is nearly empty — does this still hold?
Asking directly, because I could not find a straight answer: Pen mechanics when the cartridge is nearly empty — does this still hold? Pen mechanics — I have the observation and I do not trust my…
|
+37 | 47 | 61k | 6mo |
|
Gauge and length selection for subcutaneous injection
Gauge and length selection for subcutaneous injection Writing it up because I had to work it out twice and would rather nobody else did. A follow-up question about gauge and length selection that I did not…
|
+50 | 55 | 1.3k | 8mo |
|
Needle changes between doses on a reusable pen
Posting this under the heading it deserves: Needle changes between doses on a reusable pen Everything below is what sits behind that. The question about needle changes between doses that I actually want…
|
+34 | 38 | 1.5k | 10mo |
|
A ten-fold dose error caught before injection
A ten-fold dose error caught before injection — setting out what I have, and where I think it stops being reliable. Trying to work out what would count as evidence on ten-fold dose error caught, before…
|
+95 | 103 | 26k | 10mo |
|
Revisiting: Filter needles: when they help and what they cost you
Revisiting: Filter needles: when they help and what they cost you — setting out what I have, and where I think it stops being reliable. Trying to work out what would count as evidence on Filter needles,…
|
+48 | 52 | 6.6k | 11mo |
|
A ten-fold dose error caught before injection — one year on
On the subject in the title: A ten-fold dose error caught before injection — one year on Working notes rather than a conclusion. Two things I would like separated before anyone answers on ten-fold dose error…
|
+151 | 157 | 9.4k | 12mo |
|
Second pass at: Pen dose counters: what a click does and does not guarantee
Second pass at: Pen dose counters: what a click does and does not guarantee — setting out what I have, and where I think it stops being reliable. Two things I would like separated before anyone answers on Pen…
|
+63 | 68 | 51k | 13mo |
|
Needle changes between doses on a reusable pen — does this still hold?
Needle changes between doses on a reusable pen — does this still hold? I have a specific reason for asking rather than idle curiosity, and the context is below. Posting a small dataset on Needle changes…
|
+1 | 5 | 38k | 13mo |
|
Storing a pen in use versus a pen unopened
Storing a pen in use versus a pen unopened Writing it up because I had to work it out twice and would rather nobody else did. Proposing that storing a pen deserves a maintained page rather than a recurring…
|
+14 | 18 | 13k | 14mo |
|
Storing a pen in use versus a pen unopened — what changed since
Posting this under the heading it deserves: Storing a pen in use versus a pen unopened — what changed since Everything below is what sits behind that. What changes if the standard account of Storing a pen is…
|
2 | 206 | 15mo | |
|
Second pass at: A pen that felt like it delivered nothing: diagnosing it afterwards
Second pass at: A pen that felt like it delivered nothing: diagnosing it afterwards — setting out what I have, and where I think it stops being reliable. Question about a metering device rather than about a…
|
+9 | 13 | 829 | 18mo |
|
Fixed versus detachable needles: the trade-offs
Posting this under the heading it deserves: Fixed versus detachable needles: the trade-offs Everything below is what sits behind that. I was wrong about fixed versus detachable needles in a thread last spring…
|
+117 | 121 | 7.3k | 18mo |
|
Follow-up: Dead volume across syringe and needle combinations
Dead volume across syringe and needle combinations — setting out what I have, and where I think it stops being reliable. A follow-up question about Dead volume across syringe that I did not know to ask the…
|
+81 | 98 | 22k | 18mo |